1.
Braz. j. med. biol. res ; 57: e13155, 2024. tab, graf
Article in English | LILACS-Express | LILACS | ID: biblio-1528104

ABSTRACT

Intracranial hemorrhage (ICH) is a serious medical condition that can lead to significant morbidity and mortality if not diagnosed and treated promptly. Early detection and treatment are essential for improving the outcome in patients with ICH. Near-infrared spectroscopy (NIRS) is a non-invasive imaging technique that has been used to detect changes in brain tissue oxygenation and blood flow in various conditions. The aim of this study was to investigate the predictive potential of NIRS for early diagnosis of ICH in patients presenting to the Emergency Department (ED) triage with headache. A total of 378 patients were included in the study. According to the final diagnosis of the patients, 4 groups were formed: migraine, tension-cluster headache, intracranial hemorrhage and intracranial mass, and control group. Cerebral NIRS values "rSO2" were measured at the first professional medical contact with the patient. The right and left rSO2 (RrSO2, LrSO2) were significantly lower and the rSO2 difference was significantly higher in the intracranial hemorrhage group compared to all other patient groups (P<0.001). The cut-off values determined in the receiver operating characteristics (ROC) analysis were RrSO2 ≤67, LrSO2 ≤67, and ΔrSO2 ≥9. This study found that a difference of more than 9 in cerebral right-left NIRS values can be a non-invasive, easy-to-administer, rapid, and reliable diagnostic test for early detection of intracranial bleeding. NIRS holds promise as an objective method in ED triage for patients with intracranial hemorrhage. However, further research is needed to fully understand the potential benefits and limitations of this method.

2.
Chinese Medical Sciences Journal ; (4): 117-124, 2023.
Article in English | WPRIM | ID: wpr-981594

ABSTRACT

Background A simple measurement of central venous pressure (CVP)-mean by the digital monitor display has become increasingly popular. However, the agreement between CVP-mean and CVP-end (a standard method of CVP measurement by analyzing the waveform at end-expiration) is not well determined. This study was designed to identify the relationship between CVP-mean and CVP-end in critically ill patients and to introduce a new parameter of CVP amplitude (ΔCVP= CVPmax - CVPmin) during the respiratory period to identify the agreement/disagreement between CVP-mean and CVP-end.Methods In total, 291 patients were included in the study. CVP-mean and CVP-end were obtained simultaneously from each patient. CVP measurement difference (|CVP-mean - CVP-end|) was defined as the difference between CVP-mean and CVP-end. The ΔCVP was calculated as the difference between the peak (CVPmax) and the nadir value (CVPmin) during the respiratory cycle, which was automatically recorded on the monitor screen. Subjects with |CVP-mean - CVP-end|≥ 2 mmHg were divided into the inconsistent group, while subjects with |CVP-mean - CVP-end| < 2 mmHg were divided into the consistent group.Results ΔCVP was significantly higher in the inconsistent group [7.17(2.77) vs.5.24(2.18), P<0.001] than that in the consistent group. There was a significantly positive relationship between ΔCVP and |CVP-mean - CVP-end| (r=0.283, P <0.0001). Bland-Altman plot showed the bias was -0.61 mmHg with a wide 95% limit of agreement (-3.34, 2.10) of CVP-end and CVP-mean. The area under the receiver operating characteristic curves (AUC) of ΔCVP for predicting |CVP-mean - CVP-end| ≥ 2 mmHg was 0.709. With a high diagnostic specificity, using ΔCVP<3 to detect |CVP-mean - CVP-end| lower than 2mmHg (consistent measurement) resulted in a sensitivity of 22.37% and a specificity of 93.06%. Using ΔCVP>8 to detect |CVP-mean - CVP-end| >8 mmHg (inconsistent measurement) resulted in a sensitivity of 31.94% and a specificity of 91.32%.Conclusions CVP-end and CVP-mean have statistical discrepancies in specific clinical scenarios. ΔCVP during the respiratory period is related to the variation of the two CVP methods. A high ΔCVP indicates a poor agreement between these two methods, whereas a low ΔCVP indicates a good agreement between these two methods.


Subject(s)
Humans , Central Venous Pressure , Respiration , ROC Curve
3.
Chinese Journal of Medical Instrumentation ; (6): 43-46, 2023.
Article in Chinese | WPRIM | ID: wpr-971301

ABSTRACT

OBJECTIVE@#To use the low-cost anesthesia monitor for realizing anesthesia depth monitoring, effectively assist anesthesiologists in diagnosis and reduce the cost of anesthesia operation.@*METHODS@#Propose a monitoring method of anesthesia depth based on artificial intelligence. The monitoring method is designed based on convolutional neural network (CNN) and long and short-term memory (LSTM) network. The input data of the model include electrocardiogram (ECG) and pulse wave photoplethysmography (PPG) recorded in the anesthesia monitor, as well as heart rate variability (HRV) calculated from ECG, The output of the model is in three states of anesthesia induction, anesthesia maintenance and anesthesia awakening.@*RESULTS@#The accuracy of anesthesia depth monitoring model under transfer learning is 94.1%, which is better than all comparison methods.@*CONCLUSIONS@#The accuracy of this study meets the needs of perioperative anesthesia depth monitoring and the study reduces the operation cost.


Subject(s)
Artificial Intelligence , Neural Networks, Computer , Heart Rate , Electrocardiography , Photoplethysmography/methods , Anesthesia
5.
Chinese Journal of Blood Transfusion ; (12): 53-56, 2023.
Article in Chinese | WPRIM | ID: wpr-1004887

ABSTRACT

【Objective】 To analyze the reasons for the invalidity of blood nucleic acid test results, and to explore the countermeasures to reduce the invalidity of the test. 【Methods】 From 2019 to 2021, the number of tests performed in our laboratory for Cobas s201 blood nucleic acid screening system and the number of batches and tests with invalid results were counted, and the types and reasons of invalid results were analyzed. 【Results】 From 2019 to 2021, the Cobas s201 nucleic acid detection system detected a total of 5, 420 batches and 127, 950 pools, and the invalid rate of batches and pools were 1.83% and 1.97%, respectively. The types of invalid results can be summarized as improper operation, sample quality problems, invalid quality control (IQC), equipment failure and others. Among them, IQC and equipment failure were the main reasons for invalid results, accounting for 44.51% and 39.96%, respectively. IQC was mainly related to cross-contamination of samples and insufficient mixing of quality control products. Equipment failures mostly occurred in the robotic arm gripper of the nucleic acid extraction instrument and the TC module of the amplification instrument. 【Conclusion】 The laboratory should conduct quality monitoring for invalid results, and take targeted improvement measures, especially to reduce invalid results caused by invalid quality control and instrument failure.

6.
China Occupational Medicine ; (6): 189-193, 2023.
Article in Chinese | WPRIM | ID: wpr-996547

ABSTRACT

Occupational health literacy refers to the awareness and ability of workers to obtain basic knowledge of occupational health, practice healthy working styles and lifestyles, prevent the risk of occupational and work-related diseases, and maintain and promote their own health. In 2022, for the first time, China carried out nationwide monitoring for occupational health literacy of key populations. The National Institute for Occupational Health and Poison Control, Chinese Center for Disease Control and Prevention was responsible for technical support, formulating the National Technical Plan for Occupational Health Literacy Monitoring and Intervention of Key Populations, and formulating relevant requirements and specifications for monitoring purposes, monitoring scope and objects, sampling methods, monitoring content and methods, organization and implementation of field investigation, and quality control. In addition, the National Occupational Health Literacy Monitoring Questionnaire for Key Groups was provided, and the monitoring and intervention of occupational health literacy for key groups in the second- and third-key industries has been organized nationwide, so as to understand the occupational health literacy of the occupational population in China and provide important support for promotion of high-quality construction of healthy China.

7.
Chinese Journal of Radiation Oncology ; (6): 546-550, 2023.
Article in Chinese | WPRIM | ID: wpr-993228

ABSTRACT

Objective:To analyze the correlation between the monitor units and pass rate of plan dose verification in the volumetric intensity modulated arc therapy (VMAT) plan.Methods:VMAT plans for 20 patients with nasopharyngeal carcinoma (NPC) and 30 patients with cervical cancer who underwent radiotherapy at Liuzhou Workers' Hospital from January to October 2020 were retrospectively chosen. The Detector 1500 array and Octavius 4D phantom from German PTW company were used for dose measurement. The pass rates of dose verification of relevant plans were analyzed under the conditions of 3%/2 mm and 2%/2 mm. The correlation between the monitor units and pass rate of plan dose verification in VMAT plans was assessed by Pearson's bivariate correlation analysis.Results:Under the condition of 3%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.873 ( P<0.001), -0.800 ( P<0.001), -0.781 ( P<0.001), -0.493 ( P=0.006) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Under the condition of 2%/2 mm, the correlation coefficients between the monitor units and gamma pass rate were -0.842 ( P<0.001), -0.770 ( P<0.001), -0.748 ( P<0.001) and -0.531 ( P=0.003) for NPC_1Arc, NPC_2Arc, NPC_1Arc+NPC_2Arc and Cervix_2Arc, respectively. Conclusion:Significant negative correlation can be observed between the monitor units and plan dose verification pass rate in VMAT plan.

8.
Chinese Journal of Endemiology ; (12): 488-492, 2023.
Article in Chinese | WPRIM | ID: wpr-991659

ABSTRACT

Objective:To investigate the dynamic prevalence of Kashin-Beck disease (KBD) in 2020, and to provide the basis for assessment of KBD control and elimination.Methods:According to the "Kashin-Beck Disease Monitoring Plan (2019 Edition)", collection of basic information of endemic areas and children KBD examination were executed in all endemic areas from every endemic county (city, district, banner) of 13 endemic provinces. All children aged 7 - 12 years in endemic areas underwent clinical examination, X-ray examination was performed for clinically positive children. According to the criteria of "Diagnosis of Kashin-Beck Disease" (WS/T 207-2010), KBD cases were diagnosed by both clinical examination and X-ray check.Results:In monitoring of 827 986 children of 7 - 12 years old, a total of 703 children with similar clinical signs of KBD were suspected positive cases. X-ray results showed that 703 children were normal, with no X-ray positive change, they were not children KBD cases.Conclusions:In 2020, no cases of Kashin-Beck disease are detected in children nationwide, and the condition of Kashin-Beck disease in children nationwide continues to be at a level of elimination.

9.
Indian J Pediatr ; 2022 Nov; 89(11): 1113–1116
Article | IMSEAR | ID: sea-223736

ABSTRACT

This study aimed to evaluate available volume status assessment tools in nephrotic syndrome (NS). Sixty children with INS were subdivided into hypovolemic and nonhypovolemic groups based on fractional excretion of sodium (FeNa%); all were studied for inferior vena cava collapsibility index (IVCCI), plasma atrial natriuretic peptide (ANP), and body composition monitor (BCM). Forty-four patients had nonhypovolemic and 16 had hypovolemic states. ANP did not difer between both groups. IVCCI was higher in hypovolemic group (p<0.001) with sensitivity 87.5% and specifcity 81.8% for hypovolemia detection, while BCM overhydration (BCM-OH) values were higher in nonhypovolemic group (p=0.04) with sensitivity=68.2% and specifcity=75% for detection of hypervolemia. FeNa% showed negative correlation with IVCCI (r= ?0.578, p<0.001) and positive correlation with BCM-OH (r=0.33, p=0.018), while FeNa% showed nonsignifcant correlation to ANP concentration. IVCCI is a reliable tool for evaluating volume status in NS and is superior to BCM.

10.
Rev. chil. endocrinol. diabetes ; 15(1): 29-34, 2022. ilus
Article in Spanish | LILACS | ID: biblio-1359364

ABSTRACT

Los cuidados actuales de la diabetes incluyen altos niveles de tecnología y los pacientes utilizan diferentes dispositivos que pueden ayudar en su control metabólico, pero pueden impactar negativamente en su piel. Sensores de glucosa como el Freestyle, Dexcom, el Enlite de Medtronic y los sistemas de infusión continua de insulina contienen diferentes productos químicos que están en contacto directo con la piel del paciente y pueden causar una dermatitis irritativa o de contacto alérgica. Las lesiones incluyen eczema, prurito, heridas, cicatrices y cambios en la pigmentación de la piel. Los productos químicos involucrados que pueden ocasionarlas son el isobornil acrilato, N, N- dimetilacrilamida, etil cianoacrilato y colophonium, forzando a los pacientes a cambiar los sitios de infusión, el set de infusión o el sensor mismo más pronto de lo esperado, para reducir el nivel de daño en la piel. Existe gran número de productos que permiten proteger la piel y reducir el contacto de la piel con la cánula de la bomba o el sensor. Para reducir o prevenir el daño existen productos como cremas o spray y parches de hidrocoloide que actúan como barrera y existen técnicas para aplicar y retirar cuidadosamente los parches y adhesivos de los dispositivos. Una vez que las lesiones se han producido, el tratamiento incluye pomadas y a veces corticoides tópicos y/o antibióticos. Para prevenir o reducir el daño de la piel asociado al sensor y uso de la bomba de insulina, la industria que los produce debería incluir la información en relación a los productos químicos incluidos en cada dispositivo.


Diabetes care nowadays includes a high level of technology and patients use different devices which can help them in their glycemic control, but can have a negative impact on their skin. Glucose sensors such as Freestyle, Dexcom, Medtronic Enlite and also continuous subcutaneous insulin infusion systems contain different chemical products which are in direct contact with the patient's skin and can cause irritative or allergic contact dermatitis. Lesions include eczema, pruritus, wounds, scars and changes in skin pigmentation. The chemical products which can induce them are isobornyl acrylate, N, N- dimethylacrylamide, ethyl cyanoacrylate and colophonium, forcing patients to change the infusion site, set or the sensor itself, earlier than expected, in order to reduce the level of skin damage. There are a number of products which can protect the skin and reduce it's contact with the pump cannula or the sensor. To reduce or prevent damage, we have products such as barrier cream or spray films and hydrocolloid blister plasters and actions such as careful application and removal of device's patches and adhesives. Once lesions are established, treatment includes ointments and sometimes topical steroids and/ or antibiotics. In order to prevent or reduce skin damage related to sensor and insulin pump use, the manufacturers should include the information related to the chemicals included in each device.


Subject(s)
Humans , Skin Diseases/etiology , Insulin Infusion Systems/adverse effects , Skin/injuries , Blood Glucose Self-Monitoring/adverse effects , Adhesives/adverse effects , Dermatitis, Allergic Contact/etiology , Glycemic Control/adverse effects
11.
Chinese Journal of Industrial Hygiene and Occupational Diseases ; (12): 7-11, 2022.
Article in Chinese | WPRIM | ID: wpr-935733

ABSTRACT

Objective: To study the effects on extravascular lung water of lung protective ventilation strategy applying on piglets with acute respiratory distress syndrome (ARDS) induced by paraquat (PQ) under pulse indicating continuous cardiac output (PiCCO) monitoring. Methods: The piglets models with ARDS induced by PQ were established in June 2020 and all of them were received mechanical ventilation and divided into three groups according to tidal volume (V(T)) : small V(T) group (6 ml/kg) , middle V(T) group (10 ml/kg) and large V(T) group (15 ml/kg) , there were 5 piglets in each group. The positive end expiratory pressure (PEEP) were all setup on 10 cmH(2)O. The indexes such as arterial blood gas analysis, oxygenation index (OI) , extravascular lung water index (ELWI) and pulmonary vascular permeability index (PVPI) were monitored at time of before the model was established (baseline) , time of the model was established (t(0)) and 2 h (t(2)) , 4 h (t(4)) , 6 h (t(6)) after mechanical ventilation. Lung tissue were punctured at time of baseline, t(0) and t(6) to be stained by Hematoxylin-eosin (HE) staining and pulmonary pathology were observed under light microscopy. Results: The heart rate (HR) , mean arterial pressure (MAP) and partial pressure of carbon dioxide (PaCO(2)) of all groups were higher than the base value while the pH values, partial pressure of oxygen (PaO(2)) and OI were lower than the base value when the models were established (P<0.05) . After mechanical ventilation, the HR and MAP values of all groups at t(2), t(4) and t(6) were lower than t(0) while the PaCO(2) of t(4) and t(6) were all higher than t(0), the differences were statistically significant (P<0.05) . The PaO(2) and OI of all groups showed a trend of rising at first and then decreasing after mechanical ventilation. The MAP, PaO(2), PaCO(2) and OI of the middle V(T) group and large V(T) group were apparently lower than that of the small V(T) group at t(2), t(4) and t(6) (P<0.05) . The ELWI and PVPI at t(0) of all groups were higher than that of baseline (P<0.05) . The ELWI of the small V(T) group at t(6) were lower than t(0) of the same group and t(6) of the middle V(T) group and large V(T) group (P<0.05) . HE staining showed congestion and edema of alveolar tissue, swelling of capillaries, exudation of red blood cells and widening of alveolar septum in piglets after successful modeling. And further widening of alveolar septum and rupture of alveolar septum could be seen in the lung tissues of each group at t(6), and the injury was the slightest in the small V(T) group. Conclusion: The lung protective ventilation strategy can alleviate the extravascular lung water and ARDS induced by PQ and improve oxygenation.


Subject(s)
Animals , Extravascular Lung Water , Lung/physiology , Paraquat/toxicity , Respiration, Artificial/adverse effects , Respiratory Distress Syndrome, Newborn/chemically induced , Swine
12.
Chinese Journal of Endemiology ; (12): 200-203, 2022.
Article in Chinese | WPRIM | ID: wpr-931522

ABSTRACT

Objective:To master the epidemic trend of human brucellosis in Qinghai Province, so as to provide basis for scientific prevention and control of the disease.Methods:In 2019 and 2020, at the national and provincial brucellosis monitoring sites in Qinghai Province, a total of 18 counties (cities and districts, hereinafter referred to as counties), no less than 400 serum samples were sampled every year for brucellosis Rose-Bengal plate agglutination test (RBPT) and serum tube agglutination test (SAT), which would be tested and judged according to the criteria of "Diagnosis for Brucellosis" (WS 269-2019).Results:In 2019, a total of 1 612 people were monitored in national brucellosis monitoring sites, 93 were RBPT positive, 54 were SAT positive, 54 were diagnosed, and the prevalence rate was 3.35% (54/1 612). In 2020, 1 677 people were monitored in national brucellosis monitoring sites, 151 were RBPT positive, 80 were SAT positive, 80 were diagnosed, and the prevalence rate was 4.77% (80/1 677). There were significant differences in RBPT positive rate, SAT positive rate and prevalence rate among national monitoring sites between the two years (χ 2 = 12.52, 4.24, 4.24, P < 0.05). In 2019, a total of 6 043 people were monitored in provincial brucellosis monitoring sites, 128 were RBPT positive, 91 were SAT positive, 87 were diagnosed, and the prevalence rate was 1.44% (87/6 043). In 2020, 5 664 people were monitored, 108 were RBPT positive, 59 were SAT positive, 52 were diagnosed, and the prevalence rate was 0.92% (52/5 664). There was no significant difference in RBPT positive rate among provincial monitoring sites between the two years (χ 2 = 0.66, P = 0.416), and the differences in SAT positive rate and prevalence rate were statistically significant among provincial monitoring sites between the two years (χ 2 = 4.98, 14.57, P < 0.05). Conclusion:In 2019 and 2020, there are human brucellosis in national and provincial brucellosis monitoring sites in Qinghai Province.

13.
Chinese Journal of Medical Instrumentation ; (6): 464-468, 2022.
Article in Chinese | WPRIM | ID: wpr-939768

ABSTRACT

The accelerometry(AMG) muscle relaxant monitor is the most widely used quantitative muscle relaxant monitor to assess the degree of neuromuscular at present. In this study, the ulnar nerve was stimulated by using train of four stimulation(TOF) mode of the AMG muscle relaxant monitor, and the movement of the adductor pollicis muscle was monitored. In this way, the distribution range of key parameters (acceleration peak value, response time, and TOF ratio) of the adductor pollicis muscle during the use of muscle relaxant in clinical practice is analyzed and will provide a practical basis for the development and improvement of the muscle relaxant monitor.


Subject(s)
Electric Stimulation , Muscle, Skeletal , Neuromuscular Blockade , Neuromuscular Nondepolarizing Agents , Ulnar Nerve/physiology
14.
Shanghai Journal of Preventive Medicine ; (12): 394-398, 2022.
Article in Chinese | WPRIM | ID: wpr-924181

ABSTRACT

Due to the lack of real-time monitoring information of traditional epidemiological investigation methods, in recent years, a new method of obtaining relevant epidemiological information through wastewater analysis has become an effective way to maintain the health of the population, which is called wastewater-based epidemiology. Information obtained from the chemical analysis of wastewater can be used to estimate exposure or consumption of chemicals. This work introduces the principle and the investigation method of wastewater-based epidemiology. Compared with traditional epidemiological survey methods, the advantages and disadvantages of wastewater-based epidemiology are analyzed. Development and prospects of wastewater-based epidemiological investigation methods in China are analyzed and some suggestions are discussed.

15.
Journal of Public Health and Preventive Medicine ; (6): 71-74, 2022.
Article in Chinese | WPRIM | ID: wpr-920377

ABSTRACT

Objective In order to understand the contamination status of food-borne pathogens in food in Nantong City, and to provide a scientific basis for food safety risk assessment and supervision. Methods The monitoring was performed according to the plan of food safety risk surveillance in Nantong City and the manual on monitoring microbes and its pathogenic factors in foodstuffs of Jiangsu Province. A total of 1025 food samples of 11 kinds were monitored from 2017 to 2020 for detecting of pathogenic bacteria such as Listeria monocytogenes, Salmonella, Vibrio parahaemolyticus, Bacillus cereus and Staphylococcus aureus, and the test results were summarized, analyzed and evaluated. Results A total of 142 pathogenic bacteria were detected, with a total positive rate of 13.85%. The detection rate was the highest in 2018 (25.65%), and the lowest in 2017 (4.98%). The highest detection rate was found in meat and meat products(25.38%), followed by aquatic products and animal products (17.92%), cooked rice and flour products around the school (14.29%), the detection rate of barreled drinking water was the lowest (2.86%). 170 strains of pathogenic bacteria were detected from 1025 samples. The higher positive rate was Bacillus cereus in the cooked rice flour products around the school, and 5 strains of Bacillus cereus were detected, with the detection rate was 14.29%. 18 strains of Staphylococcus aureus were detected in meat and meat products, and the detection rate was 13.85%; 70 Vibrio parahaemolyticus were detected in aquatic products, and the detection rate was 13.49%; 16 Listeria monocytogenes were detected in meat and meat products, and the detection rate was 12.31%. The positive rate of catering links is higher than that of circulation links, and the positive rate of urban areas is higher than that of rural areas. Conclusions Pathogenic bacteria were detected in different kinds of food, and the overall situation of food safety is stable. In the future, the monitoring scope will be expanded continuously, the monitoring continuity will be strengthened, the sampling quantity will be increased, the monitoring quality will be improved, the trend of food pollution change in the city shall be mastered in time, food safety warning shall be well done, and food safety education shall be strengthened for food practitioners, food pollution risk shall be reduced and food safety shall be effectively guaranteed.

16.
Rev. bras. med. esporte ; 27(8): 773-775, Aug. 2021. tab
Article in English | LILACS-Express | LILACS | ID: biblio-1351837

ABSTRACT

ABSTRACT Introduction: Physical exercise can enhance the body's ability to adapt to the external environment and improve the contractility of the heart. At the same time, it can help improve blood circulation and increase lung capacity. Objective: This article explores the critical role of sports in the prevention of cardiovascular diseases. Methods: This article conducts tests on related physiological indicators such as hemodynamic rheology for students who regularly participate in physical exercise and those who do not participate in physical exercise. Results: Students who exercise regularly and those who do not exercise mobilize faster cardiovascular function at the beginning of work. This shows good adaptability to sports. Conclusion: The use of fitness exercise prescription by students who exercise comprehensively has the most pronounced effect on improving vascular function. Level of evidence II; Therapeutic studies - investigation of treatment results.


RESUMO Introdução: O exercício físico pode aumentar a capacidade do corpo de se adaptar ao meio ambiente e melhorar a contratilidade do coração. Ao mesmo tempo, pode reestabelecer a circulação sanguínea e aumentar a capacidade pulmonar. Objetivo: Este artigo explora o papel fundamental do esporte na prevenção de doenças cardiovasculares. Métodos: Este estudo conduziu testes em indicadores fisiológicos relacionados, tais como a reologia hemodinâmica em estudantes que regularmente praticam exercício físico e aqueles que não praticam exercício físico. Resultados: Estudantes que praticam exercícios regularmente e aqueles que não o fazem mobilizam uma função cardíaca mais rápida no início do treino, o que demonstra boa adaptabilidade ao esporte. Conclusão: A prescrição de exercícios de preparo físico para estudantes que se exercitam de forma completa tem o efeito mais pronunciado na função vascular. Nível de evidência II; Estudos terapêuticos - investigação de resultados de tratamento.


RESUMEN Introducción: El ejercicio físico puede aumentar la capacidad del cuerpo de adaptarse al medio ambiente y mejorar la contractilidad del corazón. Al mismo tiempo, puede restablecer la circulación sanguínea y aumentar la capacidad pulmonaria. Objetivo: Este artículo explora el papel fundamental del deporte en la prevención de enfermedades cardiovasculares. Métodos: Este estudio condujo pruebas en indicadores fisiológicos relacionados, como la reología hemodinámica, en estudiantes que regularmente practican ejercicio físico y los que no lo practican. Resultados: Estudiantes que practican ejercicios regularmente y los que no lo hacen movilizan una función cardíaca más rápida al principio del entrenamiento, lo que demuestra buena adaptabilidad al deporte. Conclusión: La prescripción de ejercicios de preparación física para estudiantes que se ejercitan de forma completa tiene el efecto más pronunciado en la función vascular. Nivel de evidencia II; Estudios terapéuticos - investigación de resultados de tratamiento.

17.
Journal of Peking University(Health Sciences) ; (6): 942-945, 2021.
Article in Chinese | WPRIM | ID: wpr-942279

ABSTRACT

OBJECTIVE@#With the rapid development of sleep medicine, there are various methods for detecting sleep diseases. This study compared the correlation between the lightweight watch-type sleep monitor (Actiwatch) and the "gold standard" polysomnography (PSG) in the Chinese population, in order to provide a basis for clinical application.@*METHODS@#From August 2018 to December 2019, 121 subjects who simultaneously performed sleep breathing monitoring (PSG) and wearing a watch-type sleep monitor (Actiwatch) in the Sleep Center of Peking University People's Hospital were enrolled. All subjects received PSG and Actiwatch at the same time, and filled out the sleep diary next morning. Monitoring indicators were collected for linear correlation analysis and paired t test to compare the differences.@*RESULTS@#Under low sensitivity conditions, the correlation coefficient of total sleep time (TST) between PSG and Actiwatch was 0.53 (P < 0.05). Paired t test analysis showed that there was no significant difference between the TSTs of Actiwatch and PSG (t=-0.890, P=0.36). According to age stratification, the smaller the age, the stronger the correlation between the TSTs of Actiwatch and PSG, and the coefficient could be up to 0.92 (P < 0.05). Paired t test showed that there was no significant difference between them (t=-1.057, P=0.35). According to the stratification by diagnosis, the correlation coefficient between the TSTs of Actiwatch and PSG in normal PSG group could be as high as 0.79 (P < 0.05), the results of paired t test showed that there was no significant difference between the TSTs of Actiwatch and PSG in normal PSG group (t=-0.784, P=0.44).@*CONCLUSION@#As a wearable home recorder, when the analysis parameters of Actiwatch were set as low sensitivity, PSG and Actiwatch had the highest TST correlation. The younger the age, the stronger correlation between the TSTs of Actiwatch and PSG. The PSG and Actiwatch subjects with normal PSG presentation had a higher TST correlation.


Subject(s)
Humans , Actigraphy , Polysomnography , Reproducibility of Results , Sensitivity and Specificity , Sleep , Sleep Wake Disorders , Time
18.
Journal of Peking University(Health Sciences) ; (6): 608-612, 2021.
Article in Chinese | WPRIM | ID: wpr-942226

ABSTRACT

OBJECTIVE@#To evaluate the efficacy of an electro-mechanical film-based(EMFi) multi-parameter pressure sensitive sleep monitor(MPSSM)on clinical diagnosis and research significance of obstructive sleep apnea hypopnea syndrome(OSAHS).@*METHODS@#Retrospective analysis was made of 58 test subjects at Peking University Third Hospital with suspected OSAHS who were simultaneously monitored by MPSSM and polysomnography(PSG). The PSG test results were used as the gold standard in evaluating the sensitivity and specificity of OSAHS diagnosis of MPSSM. The test result consistency of sleep apnea and hypopnea index(AHI)and total apnea time of the two methods was evaluated. Real-time waveform comparison of sleep respiratory events of a randomly selected patient diagnosed with OSAHS was performed.@*RESULTS@#For 58 test subjects, 48 were male, 10 were female, with an average age of(40.6±12.2)years. Thirty-nine out of the 58 test subjects were diagnosed with OSHAS by PSG. The sensitivity of MPSSM for OSAHS diagnosis was 92.3%, with 95% confidence interval of 79.1%-98.4%, and the specificity of MPSSM for OSAHS diagnosis was 100%, with 95% confidence interval of 82.3%-100%. Kappa test k=0.887 (P < 0.001) showed OSAHS diagnosis results of the two methods were almost identical. The AHI measured by MPSSM [12.0(2.6-32.2) times/h] and PSG [13.4(3.1-38.8) times/h] were highly correlated (ρ=0.939, P < 0.001). The total apnea time measured by MPSSM [37.9(9.9-80.5) min] and PSG [32.3(8.6-93.0) min] were highly correlated(ρ=0.924, P < 0.001). Bland-Altman plot showed that the consistency between the test results of the two methods was very high.@*CONCLUSION@#As a portable, non-contact, fully automatic monitoring device, MPSSM is reliable in the screening of OSAHS compared with PSG. It is suitable to be promoted and applied in primary medical institutions, nursing homes and domestic usage. However, further research is required in improving the analysis of different sleep phase and the differentiation of central sleep apnea syndrome respiratory events in order to effectively assist medical personnel in making an accurate sleep apnea diagnosis.


Subject(s)
Adult , Female , Humans , Male , Middle Aged , Polysomnography , Retrospective Studies , Sensitivity and Specificity , Sleep , Sleep Apnea, Obstructive/diagnosis
19.
Chinese Journal of Hospital Administration ; (12): 300-302, 2021.
Article in Chinese | WPRIM | ID: wpr-912746

ABSTRACT

The authors introduced the construction of the central monitoring system of bedside monitor in a hospital, and introduced its software and hardware design scheme and function in detail. The implementation of the system guaranteed the medical safety, reduced the workload of medical staff, improved the work efficiency, and had the characteristics of low cost and practicability.

20.
Chinese Journal of Internal Medicine ; (12): 965-969, 2021.
Article in Chinese | WPRIM | ID: wpr-911460

ABSTRACT

Objective:The underlying causes of unexplained syncope and palpitations are difficult to determine in clinical practice. This study was designed to investigate the value of the insertable cardiac monitor (ICM) for the diagnosis of the unexplained syncope and palpitations.Methods:A total of 184 patients with syncope or palpitations due to unexplained reasons were enrolled in the First Affiliated Hospital of Xinjiang Medical University (144 patients with unexplained syncope and 40 patients with unexplained palpitations) from October 2015 to October 2019. Among them, 99 patients (77 patients with unexplained syncope and 22 patients with unexplained palpitations) were received ICM implantation (the ICM implanted group) and 85 patients (67 patients with unexplained syncope and 18 patients with unexplained palpitations) were not (the non-ICM implanted group). The patients in the ICM implanted group were followed up once every 3 months until the occurrence of syncope or palpitations. During follow-up, the electrocardiograph (ECG) data recorded by ICM were collected and analyzed retrospectively. The patients in the non-ICM implanted group underwent routine follow-up.Results:The follow-up time of the ICM implanted group was (29.3±9.3) months, and the follow-up time of the non-ICM implanted group was (27.2±10.4) months. The total detection rate (syncope and palpitations) in the implanted ICM group was much higher than that in the non-ICM implanted group (38.4% vs. 3.5%, P<0.001), with syncope detection rate of 40.3% in the implanted ICM group and 3.0% in the non-ICM implanted group ( P<0.001), and palpitation detection rate of 31.8% in the implanted ICM group and 5.6% in the non-ICM implanted group ( P<0.05). Conclusions:Application of ICM greatly improved the diagnosis rate of patients with unexplained syncope and palpitations. It is recommended for patients with unexplained syncope and palpitations to implant ICM as soon as possible.